Anti-fouling FR-series reverse osmosis membrane elements
+
  • Anti-fouling FR-series reverse osmosis membrane elements

Anti-fouling FR-series reverse osmosis membrane elements

FR-series membrane elements are suitable for desalination of water with moderate salinity (TDS < 10,000 mg/L) and can be widely applied in reclaimed‑water reuse systems of various scales. They are particularly well suited for treating industrial wastewater containing low levels of organic contaminants and for handling slightly polluted water sources.

详情 Detailed description


(1) Product Positioning

FR-series membrane elements are suitable for desalination of water with moderate salinity (TDS < 10,000 mg/L) and can be widely applied in reclaimed‑water reuse systems of various scales. They are particularly well suited for treating industrial wastewater containing low levels of organic contaminants and for handling slightly polluted water sources.

(2) Product Features

A specialized membrane‑fabrication process is employed to enhance the membrane’s hydrophilicity, surface charge, and surface roughness, thereby reducing the adhesion and accumulation of foulants and microorganisms. In addition, a low‑pressure‑drop 34‑mil‑wide feed channel design effectively minimizes fouling on the membrane mesh, further improving the membrane element’s resistance to fouling and its cleanability.

(3) Product Performance

 

Model number Average water production rate GPD(m 3 /d) Stable desalination rate (%) Minimum desalination rate (%) Effective membrane area ft 2 (m 2) Inlet grid thickness (mil)
FR-8040 10500 (39.7) 99.6 99.4 400 (34) 34
FR-4040 2400 (9.0) 99.5 99.3 85 (7.9) 34

 

(a) Standard test conditions: 2000 ppm NaCl, 225 psi (15.5 bar), 25°C, pH = 7–8, recovery rate of 15%.

(b) The water production of a single membrane element may vary within a range of ±15%.

(c) Operating and Cleaning Limits

 

Maximum operating pressure 600 psi (4.14MPa) Permitted free chlorine concentration < 0.1 ppm
Maximum inlet water temperature 45℃ Influent pH range during continuous operation 2~11
Maximum inflow rate 17.0 m³/h (8040), 3.6 m³/h (4040) pH range of the feed water during chemical cleaning 1~13
Maximum feed water SDI15 5 Maximum allowable pressure drop for a single membrane element 15 psi (0.1 MPa)

Keywords: Anti-fouling FR-series reverse osmosis membrane elements

Related products

Brackish Water Reverse Osmosis BW Series Membrane Elements

BW-series membrane elements are suitable for desalination of brackish water, surface water, groundwater, and municipal tap water with a total dissolved solids content of 10,000 mg/L or less, and are widely used in industrial ultrapure water production at various scales, brackish water desalination, and advanced treatment for reclaimed water reuse, among many other applications.

Brackish Water Reverse Osmosis BW Series Membrane Elements

BW-series membrane elements are suitable for desalination of brackish water, surface water, groundwater, and municipal tap water with a total dissolved solids content of 10,000 mg/L or less, and are widely used in industrial ultrapure water production at various scales, brackish water desalination, and advanced treatment for reclaimed water reuse, among many other applications.

Seawater Desalination Reverse Osmosis SW Series Membrane Elements

SW-series membrane elements are suitable for desalination of high-salinity water (TDS < 45,000 mg/L) and are widely used in seawater desalination, the treatment of highly saline brackish water, as well as the concentration and reuse of high-salinity wastewater, among many other applications.

Seawater Desalination Reverse Osmosis SW Series Membrane Elements

SW-series membrane elements are suitable for desalination of high-salinity water (TDS < 45,000 mg/L) and are widely used in seawater desalination, the treatment of highly saline brackish water, as well as the concentration and reuse of high-salinity wastewater, among many other applications.

Anti-fouling FR-series reverse osmosis membrane elements

FR-series membrane elements are suitable for desalination of water with moderate salinity (TDS < 10,000 mg/L) and can be widely applied in reclaimed‑water reuse systems of various scales. They are particularly well suited for treating industrial wastewater containing low levels of organic contaminants and for handling slightly polluted water sources.

Anti-fouling FR-series reverse osmosis membrane elements

FR-series membrane elements are suitable for desalination of water with moderate salinity (TDS < 10,000 mg/L) and can be widely applied in reclaimed‑water reuse systems of various scales. They are particularly well suited for treating industrial wastewater containing low levels of organic contaminants and for handling slightly polluted water sources.

Ultra-Low-Pressure Reverse Osmosis ULP Series Membrane Elements

ULP-series membrane elements are suitable for desalination applications using municipal tap water or groundwater as the feedwater source, under low-salinity conditions (TDS < 1000 mg/L). They are primarily employed in large-scale residential water supply systems, purified water production, and the preparation of industrial-grade pure water for food, beverage, and other industries.

Ultra-Low-Pressure Reverse Osmosis ULP Series Membrane Elements

ULP-series membrane elements are suitable for desalination applications using municipal tap water or groundwater as the feedwater source, under low-salinity conditions (TDS < 1000 mg/L). They are primarily employed in large-scale residential water supply systems, purified water production, and the preparation of industrial-grade pure water for food, beverage, and other industries.